1 Operating Characteristics
Rated voltage: 0.6/1kV
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
When the diameter of cable is less than 25mm: not less than 4 times of the diameter of cable
When the diameter of cable is not less than 25mm: not less than 6 times of the diameter of cable
When the cable is used in alternative current system, the rated voltage of cable should be at least equal to the rated voltage of system; when the cable is used in direct current system, the rated voltage of system should not greater than 1.5 times of the rated voltage of the cable.

 

  

2. Application Properties

2.1.ABC cable is primarily used on lighting,outdoor lighting,and temporary service for construction.

2.2.The conductor longterm maximum working temperature: PE insulation should not exceed 75°C, XLPE insulation should not exceed 90°C.

2.3.During short circuit (maximum permanent time is not more than 5 seconds), the maximum temperature of cable conductor: XLPE insulation 250 °C, High-density polyethylene insulation 150°C. 

2.4.When laying the cable,minimum ambient temperature of laying should not be lower than -20°C.

2.5.The minimum bending radius: ≥20 (D+d) ±5mm, D is the cable overall diameter, d is the conductor diameter.

 

3.ABC cable meets or exceeds the following specifications:

3.1. Aluminum cable,1350-H19 for electrical purposes.

3.2. Aluminum conductors,concentric-lay-stranded.

3.3.Aluminum conductors,concentric-lay-stranded,coated steel reinforced(ACSR).

3.4.Concentric-lay-stranded 6201-T81 conductors.

3.5.Compressed round stranded aluminum conductors using single input conductor.

ABC cable meets or exceeds all applicable requirements of ANSI /ICEA S-76-474.

 

 

Duplex Service Drop
1Application
Primarily used for 120volt overhead service application such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160

Triplex Service Drop
1Application
Used to supply power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
 

Quadruplex Service Drop
1Application
Used to supply 3-phase power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280
 

 

 

 

Factory Equipment

 

Certifications

 

FAQS

Q1: Is your company a factory or trade company ?
A: We are  factories, more than 20 years in China.

 

Q2: What's the quality assurance we can provide and how do we control quality?
A:100% inspection on assembly lines. All controls, inspections, equipment, fixtures, total production resources and skills are inspected to confirm they consistently achieve the required quality levels.

 

Q3: What's your payment terms?

A: We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated.

 

Trade assurance on Alibaba is also available.

Q4: What’s the delivery time?

A:  Formal order needs 1025 days.

 

Q5: Can I get some samples? 

A: Yes, sample order is available for quality check and market test.

 

Q6: Do you have the products in stock?

A: Yes, we will keep some general ones in stock.

 

Q7; What is your MOQ?
 A: It`s base on the cable type or wire type. We also accept Small order .

 

Q8; Where is your factory ?
 A: we are in henan , middle of china  .