Overhead bare conductor AAC AAAC ACSR has been widely used in power transmission lines with various voltage levels.
1. Applications
Overhead bare conductor AAC AAAC ACSR has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2. Material Standard
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048- 1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced.
AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
Code Name |
Area (mm2) |
Number of wiires No. |
Wire diameter (mm) |
Conductor diameter (mm) |
Approx Weight (kg/km) |
Calcualted Min. Breaking Load (KN) |
Calculated D C Resistance at 20℃(Ω/km) |
16 |
15.9 |
7 |
1.7 |
5.1 |
43.4 |
3.02 |
1.7986 |
25 |
24.2 |
7 |
2.1 |
6.3 |
66.3 |
4.36 |
1.1787 |
35 |
34.4 |
7 |
2.5 |
7.5 |
93.9 |
6.01 |
0.8317 |
50 |
49.5 |
7 |
3 |
9 |
135.2 |
8.41 |
0.5776 |
50 |
48.3 |
19 |
1.8 |
9 |
132.9 |
8.94 |
0.5944 |
70 |
65.8 |
19 |
2.1 |
10.5 |
180.9 |
11.85 |
0.4367 |
95 |
63.3 |
19 |
2.5 |
12.5 |
256.3 |
16.32 |
0.3061 |
120 |
117 |
19 |
2.8 |
14.5 |
321.5 |
19.89 |
0.2456 |
150 |
147.1 |
37 |
2.25 |
15.8 |
405..7 |
26.48 |
0.196 |
185 |
181.6 |
37 |
2.5 |
17.5 |
500.9 |
31.78 |
0.1588 |
240 |
242.5 |
61 |
2.25 |
20.3 |
671.1 |
43.66 |
0.1193 |
300 |
299.4 |
61 |
2.5 |
22.5 |
828.5 |
52.4 |
0.0966 |
AAAC Technical Characteristics Based on Standard BS 3242
Code Name |
Nominal Aluminum Area (mm2) |
Stranding Wire No. and Dia. (No./mm) |
Sectional areas (mm2) |
Approx Overall Dia. (mm) |
Approx mass (kg/km) |
Calculated D.C. Resistance at 20℃ (Ω/km) |
Calcualted Min. Breaking Load (KN) |
ALMOND |
25 |
7/2.34 |
30.1 |
7.02 |
82 |
1.094 |
8.44 |
CEDAR |
30 |
7/2.54 |
35.47 |
7.62 |
97 |
0.9281 |
9.94 |
FIR |
40 |
7/2.95 |
47.84 |
8.85 |
131 |
0.688 |
13.4 |
HAZEL |
50 |
7/3.30 |
59.87 |
9.9 |
164 |
0.5498 |
16.8 |
OAK |
100 |
7/4.65 |
118.9 |
13.95 |
325 |
0.2769 |
33.3 |
ASH |
150 |
19/3.48 |
180.7 |
17.4 |
497 |
0.183 |
50.65 |
ELM |
175 |
19/3.76 |
211 |
18.8 |
580 |
0.1568 |
59.1 |
UPAS |
300 |
37/3.53 |
362.1 |
24.71 |
997 |
0.09155 |
101.5 |
ACSR Technical Characteristics Based on Standard BS 215-2
Code Name |
Nominal Aluminum Area (mm2) |
Stranding Wire No. and Dia. (No./mm) |
Sectional areas of aluminum (mm2) |
Total sectional area (mm2) |
Approx Overall Dia. (mm) |
Approx. Mass (kg/km) |
Calculated D C Resistance at 20℃(Ω/km) |
Calcualted Breaking Load(KN) |
|
Al |
Steel |
||||||||
RABBIT |
50 |
6/3.35 |
1/3.35 |
52.88 |
61.7 |
10.05 |
214 |
0.5426 |
18.35 |
DOG |
100 |
6/4.72 |
7/1.57 |
105 |
118.5 |
14.15 |
394 |
0.2733 |
32.7 |
WOLF |
150 |
30/2.59 |
7/2.59 |
158.1 |
194.9 |
18.13 |
726 |
0.1828 |
69.2 |
DINGO |
150 |
18/3.35 |
1/3.35 |
159.7 |
167.5 |
16.75 |
506 |
0.1815 |
35.7 |
LYNX |
175 |
30/2.79 |
7/2.79 |
183.4 |
226.2 |
19.53 |
842 |
0.1576 |
79.8 |
ZEBRA |
400 |
54/3.18 |
7/3.18 |
428.9 |
484.5 |
28.62 |
1621 |
0.0674 |
131.9 |
Overhead bare conductor has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
1. Are you the factory or trading company?
We are the manufacturer and 13 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
2. When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
3. How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.
4. What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
5. What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
- Next: Copper core pvc insulation 1.5mm Wire Electrical Building Wire
- Previous: Factory Supplying abc power cable low voltage aerial bundled